Product Details
Place of Origin: Guangdong, China
Brand Name: other
Model Number: CloudEngine S16700-8
Payment & Shipping Terms
Minimum Order Quantity: 2 units
Price: $12,900.00/units 2-99 units
Packaging Details: Carton or wooden box
Supply Ability: 1000 Unit/Units per Month
Type: |
Enterprise Switch |
Use: |
Large Enterprises, Data Centers, High Load Servers |
Model: |
CloudEngine S16700-8 |
Port: |
32 100GE QSFP28, 1 10GE SFP+ |
Exchange Capacity: |
6.4Tbps/102.4Tbps |
Packet Forwarding Rate: |
2003Mpps |
Data Center Features: |
VXLAN Routing And Bridging BGP-EVPN M-LAG PFC, ECN |
O&M: |
Telemetry IOAM (INT) Netstream SFlow ERSPAN Enhancement |
Quality: |
100% Original 100% Brand |
Dimensions (H X W X D): |
990 Mm X 770 Mm X 1150 Mm |
Weight: |
253.1kg |
Chassis Height: |
15.8U |
Type: |
Enterprise Switch |
Use: |
Large Enterprises, Data Centers, High Load Servers |
Model: |
CloudEngine S16700-8 |
Port: |
32 100GE QSFP28, 1 10GE SFP+ |
Exchange Capacity: |
6.4Tbps/102.4Tbps |
Packet Forwarding Rate: |
2003Mpps |
Data Center Features: |
VXLAN Routing And Bridging BGP-EVPN M-LAG PFC, ECN |
O&M: |
Telemetry IOAM (INT) Netstream SFlow ERSPAN Enhancement |
Quality: |
100% Original 100% Brand |
Dimensions (H X W X D): |
990 Mm X 770 Mm X 1150 Mm |
Weight: |
253.1kg |
Chassis Height: |
15.8U |
Item | CloudEngine S16700-4 | CloudEngine S16700-8 |
mounting ears and cable management frames | ears and cable management frames | |
Chassis height [U] | 9.8 U | 15.8 U |
Weight without packaging [kg(lb)] | 94.1 kg (AC input) | 129.8 kg (AC input) |
98.1 kg (DC input) | 135.8 kg (DC input) | |
Weight without packaging (full configuration) [kg(lb)] | 162 kg (AC input) | 253.1 kg (AC input) |
163.6 kg (DC input) | 255.1 kg (DC input) | |
Switching capacity | 28.8 Tbit/s | 57.6 Tbit/s |
Packet forwarding rate | 17760Mpps | 35520Mpps |
MPU slot | 2 | 2 |
LPU slot | 4 | 8 |
SFU slot | 6 (can be expanded to 9 in the future) | 6 (can be expanded to 9 in the future) |
Fan module | 3 | 3 |
System Power Supplies | 6, dual inputs supported | 10, dual inputs supported |
Redundant power supply | ⚫ Dual-input power supply system: N+1 backup is recommended. | ⚫ Dual-input power supply system: N+1 backup is recommended. |
⚫ Single-input power supply system: N+1 backup | ⚫ Single-input power supply system: N+1 backup | |
Dual-input power supply is recommended to ensure reliability. | Dual-input power supply is recommended to ensure reliability. | |
Redundant fans | Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. | Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Rated input voltage | ⚫ AC input: 220 V; 50 Hz/60 Hz | ⚫ AC input: 220 V; 50 Hz/60 Hz |
⚫ High-voltage DC (HVDC) input: 240 V/380 V | ⚫ HVDC input: 240 V/380 V | |
⚫ DC input: –48 V/–60 V | ⚫ DC input: –48 V/–60 V | |
Input voltage range | ⚫ AC: 176 V to 290 V, 45 Hz to 65 Hz | ⚫ AC: 176 V to 290 V, 45 Hz to 65 Hz |
⚫ HVDC: 188 V to 288 V/260 V to 400 V | ⚫ HVDC: 188 V to 288 V/260 V to 400 V | |
⚫ DC input: –40 V to –72 V | ⚫ DC input: –40 V to –72 V | |
Maximum power consumption | 4664 W | 8260W |
Maximum power output capability (including the system power output and PoE power output) [W] | AC input: | AC input: |
⚫ 5+1 backup: 3000 W x 5 = 15000 W | ⚫ 9+1 backup: 3000 W x 9 = 27000 W | |
⚫ 6+0 backup: 3000 W x 6 = 18000 W | ⚫ 10+0 backup: 3000 W x 10 = 30000 W | |
DC input: | DC input: | |
⚫ 5+1 backup: 2200 W x 5 = 11000 W | ⚫ 9+1 backup: 2200 W x 9 = 19800 W | |
⚫ 6+0 backup: 2200 W x 6 = 13200 W | ⚫ 10+0 backup: 2200 W x 10 = 22000 W | |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 140°F) | 0°C to 40°C (32°F to 140°F) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | –40°C to +70°C (–40°F to +158°F) |
Relative humidity | 5% RH to 85% RH (non-condensing) | 5% RH to 85% RH (non-condensing) |
Heat dissipation mode | Drawing air for heat dissipation | Drawing air for heat dissipation |
Airflow direction | Front-to-rear airflow | Front-to-rear airflow |