Send Message
Beijing Shandian Technology Co., Ltd.
products
products
Home > products > Switch Router Firewall > Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power

Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power

Product Details

Place of Origin: Guangdong, China, guangdong, China

Brand Name: HUA WEI

Payment & Shipping Terms

Minimum Order Quantity: 2 pieces

Price: $8,500.00/pieces 2-49 pieces

Get Best Price
Highlight:
Max. LAN Data Rate:
1000Mbps
With Modem Function:
NO
Standards And Protocols:
Wi-Fi 802.11ax
Wi-Fi Supported Frequency:
2.4G & 5G
Supports WDS:
No
Supports WPS:
No
Wi-Fi Transmission Standard:
WiFi 802.11 Ax
Wired Transfer Rate:
10/100/1000Mbps
2.4G Wi-Fi Transmission Rate:
1200 Mbps
Encryption Type:
WPA2-Enterprise, WPA, WPA-Enterprise, WPA2-Personal
Private Mold:
NO
Products Status:
New, Stock
Type:
Wireless
Application:
Multi-service
Function:
Voip, QoS, VPN
LAN Ports:
4
WAN Ports:
1 X10/100/1000Mbps
5G Wi-Fi Transmission Rate:
433Mbps
Architecture:
Netengine40e Universal Service Router
Port Capability:
Supports Various Interface Types (E1, Ge, Fe,Wan,L
Storage Altitude:
Less Than 5000 M (16404 FT.)
AC Input Voltage:
180 V To 264 V
Redundant Mpus:
1:1
Operating Temperature:
32° To 104° F (0° To 40° C)
Mttr:
0.5 Hours
DC Input Voltage:
-48 V/ -60 V
Max. LAN Data Rate:
1000Mbps
With Modem Function:
NO
Standards And Protocols:
Wi-Fi 802.11ax
Wi-Fi Supported Frequency:
2.4G & 5G
Supports WDS:
No
Supports WPS:
No
Wi-Fi Transmission Standard:
WiFi 802.11 Ax
Wired Transfer Rate:
10/100/1000Mbps
2.4G Wi-Fi Transmission Rate:
1200 Mbps
Encryption Type:
WPA2-Enterprise, WPA, WPA-Enterprise, WPA2-Personal
Private Mold:
NO
Products Status:
New, Stock
Type:
Wireless
Application:
Multi-service
Function:
Voip, QoS, VPN
LAN Ports:
4
WAN Ports:
1 X10/100/1000Mbps
5G Wi-Fi Transmission Rate:
433Mbps
Architecture:
Netengine40e Universal Service Router
Port Capability:
Supports Various Interface Types (E1, Ge, Fe,Wan,L
Storage Altitude:
Less Than 5000 M (16404 FT.)
AC Input Voltage:
180 V To 264 V
Redundant Mpus:
1:1
Operating Temperature:
32° To 104° F (0° To 40° C)
Mttr:
0.5 Hours
DC Input Voltage:
-48 V/ -60 V
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power
PRODUCT DESCRIPTION
Hua wei NetEngine40E Universal Service Router (NE40E)
NE40E-X3(02355250 CR5B0BKP0370): Integrated AC Chassis Components, (Including Dual AC Power) Hua wei NetEngine40E Universal Service Router (NE40E) Series routers are high-end network products developed by Hua wei. The NE40E Series includes the NE40E-X3, NE40E-X8, NE40E-X16, NE40E-X3A, NE40E-X8A and NE40E-X16A. The NE40E Series routers are usually deployed at core nodes on enterprise wide area networks (WANs), access nodes on large-scale enterprise networks, interconnection and aggregation nodes on campus networks, and edge nodes on large-scale Internet Data Center (IDC) networks. The NE20E, NE40E, and NE5000E can work together to provide a complete hierarchical IP network solution.
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 0
Features: The NE40E Series routers run on the Versatile Routing Platform (VRP) operating system and use hardware-based forwarding and non-blocking switching technologies. Based on distributed hardware forwarding, non-blocking switching technologies, distributed Clos architecture, and industry-leading 2T bps platform, the NE40E Series routers have the following features: ☆Support for 1T routing line cards in each slot, with excellent compatibility with currently used line cards to protect carriers' investments to the largest extent. ☆Line speed forwarding capabilities, industry-leading reliability, excellent scalability, a well-designed quality of service (QoS) mechanism, and strong service processing capabilities. ☆Powerful service access and aggregation capabilities and various features, such as Layer 2 virtual private network (L2VPN), L3VPN, multicast, multicast VPN (MVPN), and Multiprotocol Label Switching - Traffic Engineering (MPLS-TE). ☆Various service features, such as IP Security (IPSec), Network Address Translation (NAT), and NetStream. ☆Support for IPv6 and smooth transition from IPv4 to IPv6. The NE40E can be flexibly deployed at the edge or core of IP or MPLS networks, simplifying network structure. With its ability to provide an extensive range of services and reliable service quality, the NE40E is driving IP and MPLS bearer networks to develop greater broadband capacity and to become more secure, more intelligent, and more service-oriented.
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 1
TECHNICAL SPECIFICATION
1.Features
Features
Description
Powerful Service Support
Port capability
The NE40E supports various interface types (E1, POS, CPOS, FE, GE, 10GE-LAN/WAN, 25GE, 40GE, 50GE, and 100GE) and high-density
fixed ports to provide access and aggregation WAN services as well as Ethernet multi-service transmission platform (MSTP)
aggregation services, satisfying various service requirements. Support dedicated interface for out-of-band management 10/100/1000
and RJ-45 interface for time synchronization.
Routing
RIP, RIPng, OSPF, OSPFV3, IS-IS, IS-ISV6, BGP, BGPv6, Static routing, IPv4 Multicast, IPv6 Multicast, Multicast static, etc
IPv4
TCP/IP, for example, ICMP, IP, TCP, UDP, Socket (TCP/UDP/RAW IP), ARP Static DNS, DNS Client ,FTP Server, FTP Client ,TFTP Client,
DHCP Relay ,DHCP Server ,Ping ,Tracert ,NQA ,IP policy-based routing,
Forwarding next hop based on traffic IP policy-based route load balancing
The QinQ interface (QinQ termination and dot1q termination) supports IPv4 load balancing.
Enabling and disabling the rapid ping reply function based on interface boards
Forcible fragmentation for packets with length greater than MTU and DF enabled MPLS-in-UDP tunnel egress
PIM Multicast
IPv6
IPv6(ND),Path MTU (PMTU),TCP6, Ping IPv6, Tracert IPv6, Socket IPv6, DHCPv6 Relay, Static IPv6 DNS, TFTP IPv6 Client,IP
policy-based routing, IPv6 ND fast reply,PIM Multicast
L2VPN
PWE3/VLL,VPLS,EVPN,EVPN L3VPN,VxLAN,L2TP
L3VPN
CE routers can access the L3VPN through L3 interfaces. MP-BGP, RSVP-TE P2MP
Support static routes between CE and PE, BGP, RIP, OSPF and ISIS
Inter-AS VPN, including RFC2547bis option A.
Inter-AS VPN, including RFC2547bis option B
Inter-AS VPN, including RFC2547bis option C
NG-MVPN
IPv6 VPN
HoVPN
Seamless MPLS
BGP LSP entropy label
Redirect to VPN
L3VPN PIPE/Uniform mode
L3VPN Statistics
SRv6
SRv6-BE,SRv6 Policy,SRv6 egress protection
VAS
BNG/BRAS,NAT/CGN,IPSec,MACSec
Clock
Physical layer synchronization,1588v2 Optional support of ITU-T G8273.2 Class C
OAM
iFIT IPFPM NQA TWAMP BFD
MPLS OAM MPLS-TP OAM VRRP
Ethernet OAM 802.3ah Y1731
Ethernet LPT
Bit-error-triggered protection switching
QoS
QPPB,Differ-Serv,HQoS,Redirection
2.Product Specifications
Item
NE40E-X3
NE40E-X8
NE40E-X16
NE40E-X3A
NE40E-X8A
NE40E-X16A
Switching capacity
1.08 Tbps
7.08 Tbps (LPUF- 240/LPUI-240)
12.58 Tbps (LPUF- 240/LPUI-240)
2.76 Tbps
l 25.16 Tbps (LPUI-1T)
l 51.2 Tbps (LPUI-2T)
l 50.32 Tbps (LPUI-1T)
l 81.92 Tbps (LPUI-2T)
Forwarding performance
l 105 Mpps (LPUF-51)
l 360 Mpps (LPUF-120)
2800 Mpps (LPUF-240)
5600 Mpps (LPUF-240)
900 Mpps (LPUF-200)
2800 Mpps (LPUF-240)
5600 Mpps (LPUF-240)
Number of slots supported
5
11
22
5
12
22
Number of interface board slots supported Redundant MPUs
1:1
1:1
1:1
1:1
1:1
1:1
Redundant Switch fabrics
N/A
2+1
3+1
N/A
3+1
3+1
MTBF
27.44 years
21.91 years
21.66 years
22.85 years
22.32 years
22.33 years
MTTR
0.5 hours
0.5 hours
0.5 hours
0.5 hours
0.5 hours
0.5 hours
Availability
0.99999792
0.999997395
0.999997365
0.999997502
0.999997443
0.9999974444
Dimensions (H x W x D)
l DC: (4 U)
175 mm x442 mm x
650 mm (6.89 in. x
17.40 in. x25.59 in.)
l AC: (5 U)
220 mm x442 mm x650 mm
(8.66 in. x17.40 in. x 25.59 in.)
l (14 U) 620
mm x 442
mm x 650
mm (24.41
in. x 17.40
in. x 25.59 in.)(Chassis main body)
l (14 U) 620
mm x 442
mm x 770
mm (24.41
in. x 17.40
in. x 30.31 in.)(Dimens ions of the chassis body together with cable trays and front and back attachment s)
l (32 U) 1420
mm x 442
mm x 650
mm (55.91
in. x 17.40
in. x 25.59 in.) (Chassis main body)
l (32 U) 1420
mm x 442
mm x 770
mm (55.91
in. x 17.40
in. x 30.31 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
l (6 U) 264
mm x 442
mm x 710
mm (10.39
in. x 17.40
in. x 27.95 in.) (Chassis main body)
l DC: (6 U)
264 mm x
442 mm x
758 mm
(10.39 in. x
17.40 in. x
29.84 in.)
(Dimension s of the chassis body together with cable trays and front and back attachment s)
l AC: (6 U)
264 mm x
442 mm x
770 mm
(10.39 in. x
17.40 in. x
30.31 in.)
(Dimension s of the chassis body together with cable trays and front and back attachment s)
l (21 U) 930
mm x 442
mm x 650
mm (36.61
in. x 17.40
in. x 25.59 in.) (Chassis main body)
l (21 U) 930
mm x 442
mm x 750
mm (36.61
in. x 17.40
in. x 29.53 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
l [2T
bundle](21
U) 930 mm
x 442 mm x 941 mm
(36.61 in. x
17.40 in. x
37.05 in.)
(Dimension s of the chassis body together with cable trays and front and back attachment s and noise reduction module)
l (40 U) 1778
mm x 442
mm x 650
mm (70.00
in. x 17.40
in. x 25.59 in.) (Chassis main body)
l (40 U) 1778
mm x 442
mm x 750
mm (70.00
in. x 17.40
in. x 29.53 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
l [2T
bundle](40 U) 1778
mm x 442
mm x 946
mm (70.00
in. x 17.40
in. x 37.24 in.) (Dimension s of the chassis body together with cable trays and front and back attachment s)
Weight (empty)
l DC: 12 kg
(26.46 lb)
l AC: 20 kg
(44.1 lb)
25.8 kg (56.89
lb) (without filler panels)
69.6 kg
(153.47 lb)
(without filler panels)
26 kg (57.33
lb)
l DC: 68.1 kg
(150.16 lb)
(without filler panels)
l HVDC&AC:
63.7 kg
(140.46 lb)
(without filler panels)
l DC: 120.5
kg (265.7
lb) (without filler panels)
l HVDC&AC:
111.7 kg
(246.3 lb)
(without filler panels)
Weight (full configuration)
l DC: 42 kg (92.61 lb)
l AC: 52 kg (114.66 lb)
136 kg (299.88 lb)
279 kg (615.2 lb)
l DC: 72.1 kg (158.98 lb)
l AC: 74.7 kg (164.71 lb)
l [1T bundle] DC:209 kg (460.85 lb)
l [1T bundle] HVDC&AC:206.5 kg (455.33 lb)
l [2T bundle] DC:242kg (533.51 lb)
l [2T bundle] AC&HVDC:234.4kg(516.76 lb)
l [1T bundle] DC:399.4 kg (880.68 lb)
l [1T bundle] HVDC&AC:395.1 kg (871.2 lb)
l [2T bundle] DC:461.3kg(1017.0 lb)
l [2T bundle] HVDC&AC:453.3kg(999.34 lb)
Cabinet installation standard
Can be installed in a standard 19"800 mm-deep cabinet. A Huawei 2.2 m- high N68E cabinet is used by default.
Can be installed in a standard 19"800 mm-deep cabinet. A Huawei 2.2 m- high N68E cabinet is used by default.
Can be installed in a standard 19"800 mm-deep cabinet. A Huawei 2.2 m- high N68E cabinet is used by default.
Can be installed in a standard 19"
800 mm-deep cabinet. A Huawei 2.2 m- high N68E cabinet is used by default.
l Can be installed in a standard 19" 800mm-deep cabinet. A Huawei 2.2 m-high N68E
cabinet is used by default.
l [2T bundle] Can be installed in a standard 19" 1000mm-deep cabinet,part number is 02115109( CR5B0N61 0E60)
l Can be installed in a standard 19" 800
mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
l [2T bundle] Can be installed in a standard 19" 1000mm-deep cabinet,part number is 02115109( CR5B0N61 0E60)
Typical power consumption
l DC: 800W
(fully configured with LPUF- 51s)
l AC: 950W
(fully configured with LPUF- 51s)
l DC: 920W
(fully configured with LPUF- 120s)
l AC: 1070 W(fully configured with LPUF- 120s)
3220 W (fully configured with LPUF-240s)
6210 W (fully configured with LPUF-240s)
1120 W (fully configured with LPUF-200s)
l 4110 W
(fully configured with LPUF240s)
l 4770 W
(fully configured with LPUF480s)
l 6520 W
(fully configured with LPUI- 1Ts)
l 11100 W
(fully configured with LPUI- 2Ts)
l 7720W(fully configured with LPUF- 240s)
l 9040W(fully configured with LPUF- 480s)
l 12390W(fully configured with LPUI- 1Ts)
l 22450W(fully configured with LPUI- 2Ts)
Typical heat dissipation
l DC: 2595.5
BTU/hour (fully configured with LPUF- 51s)
l AC: 3082.2
BTU/hour (fully configured with LPUF- 51s)
l DC: 2984.9
BTU/hour (fully configured with LPUF- 120s)
l AC: 3471.5
BTU/hour (fully configured with LPUF- 120s)
10447
BTU/hour (fully configured with LPUF-240s)
20147.9
BTU/hour (fully configured with LPUF-240s)
3633.8
BTU/hour (fully configured with LPUF-200s)
l 13334.6
BTU/hour (fully configured with LPUF- 240s)
l 15475.9
BTU/hour (fully configured with LPUF- 480s)
l 21153.6
BTU/hour (fully configured with LPUI- 1Ts)
l 36013.1
BTU/hour (fully configured with LPUI- 2Ts)
l 25046.9
BTU/hour (fully configured with LPUF- 240s)
l 29329.6
BTU/hour (fully configured with LPUF- 480s)
l 40198.4
BTU/hour (fully configured with LPUI- 1Ts)
l 72837.2
BTU/hour (fully configured with LPUI- 2Ts)
DC input voltage
l input voltage range : –38.4 V to –72 V
l input rated voltage: – 48 V/ –60 V
l input voltage range: –38.4 V to –72 V
l input rated voltage: – 48 V/ –60 V
l input voltage range: –38.4 V to –
72 V
l input rated voltage: – 48 V/ –60 V
l input voltage range: – 40 V to –72 V
l input rated voltage: – 48 V/ –60 V
l input voltage range: – 40 V to –72 V
l input rated voltage: – 48 V/ –60 V
l input voltage range: – 40 V to –72 V
l input rated voltage: -48 V/–60 V
AC input voltage
l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
l input voltage range: 180 V to 264 V
l input rated voltage:200 V to 240 V
Redundant powers
1+1
2+2
4+4
1+1
l [1T bundle] DC: 5+1
l [1T bundle] HVDC&AC: 4+1
l [2T bundle] DC: 7+1
l [2T bundle] HVDC&AC: 5+1
l [1T bundle] DC: 9+1
l [1T bundle] HVDC&AC: 7+1
l [2T bundle] DC: 12+1
l [2T bundle] HVDC&AC: 9+1
Redundant fans
Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l 2 assemblies
l Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l 2 partitions
l 2 assemblies/ partition, each partition in support for proper fan operation in case of a single fan failure for a short period
at 40°C (104°F)
Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l [1T bundle] 3
assemblies
in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l [2T bundle] 3
assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
l [1T bundle] 2 partitions;
3 assemblies/ partition; each partition in support for proper fan operation in case of a single fan failure for a short period at
40°C (104°F)
l [2T bundle] 2 partitions;
3assemblies/ partition; each partition in support for proper fan operation in case of a single fan failure for a short period at
40°C (104°F)
Airflow
Operating temperature
l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:–5°C to +55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:
–5°C to
+55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:
–5°C to
+55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:
–5°C to
+55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:
–5°C to
+55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
l Long-term: 0°C to 45°C (32°F to 113°F)
l Short-term:
–5°C to
+55°C (23°F to131°F)
l Remark:Restriction on the temperatur e variation rate: 30°C/hour (86°F/h)
Storage temperature
–40°C to +70°C (–40°F to +158°F)
–40°C to
+70°C (–40°F to +158°F)
–40°C to
+70°C (–40°F to +158°F)
–40°C to
+70°C (–40°F to +158°F)
–40°C to
+70°C (–40°F to +158°F)
–40°C to
+70°C (–40°F to +158°F)
Relative operating humidity
l Long term: 5% to 85% RH, non-condensing
l Short term: 5% to 95% RH, non- condensing
l Long term: 5% to 85%
RH, non-
condensing
l Short term: 5% to 95%
RH, non- condensing
l Long term: 5% to 85%
RH, non-
condensing
l Short term: 5% to 95%
RH, non- condensing
l Long term: 5% to 85%
RH, non-
condensing
l Short term: 5% to 95%
RH, non- condensing
l Long term: 5% to 85%
RH, non-
condensing
l Short term: 5% to 95%
RH, non- condensing
l Long term: 5% to 85%
RH, non-
condensing
l Short term: 5% to 95%
RH, non- condensing
Relative storage humidity
5% to 95% RH,non- condensing
5% to 95% RH,
non- condensing
5% to 95% RH,
non- condensing
5% to 95% RH,
non- condensing
5% to 95% RH,
non- condensing
5% to 95% RH,
non- condensing
Long-term operating altitude
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
Storage altitude
Less than 5000m (16404 ft.)
3.Ordering Information----NE40E-X3 Basic Configurations
BOM Number
Order Name
Description
02351596
CR52-BKPE- 4U-DC
Integrated DC Chassis Components(NE40E- X3)-4U,Including Dual DC Power
02355250
CR5B0BKP037 0
NE40E-X3 Integrated AC Chassis Components, (Including Dual AC Power)
03055705
CR5D0MPUD2 70
Main Processing Unit D3(Including 4G Memory and 2G USB)
02358577
CR5P03BASD7 3
NE40E-X3 Basic Configuration (Include NE40E- X3 Chassis,2 MPUs, 2 DC Power,without Software Charge and Document)
02358578
CR5P03BASA7 3
NE40E-X3 Basic Configuration (Include NE40E- X3 Chassis,2 MPUs, 2 AC Power(2200W),without Software Charge and Document)
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 2
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 3
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 4
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 5
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 6
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 7
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 8
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 9
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 10
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 11
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 12
COMPANY PROFILE
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 13
Why Choose Us
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 14
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 15
Exhibition
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 16
Certifications
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 17
Client Evaluation
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 18
Packing & Delivery
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 19
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 20
1. Who are we?
We are based in Beijing, China, start from 2023,sell to Domestic Market(60.00%),North America(20.00%),South America(10.00%),Western Europe(10.00%). There are total about 11-50 people in our office.

2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3. What can you buy from us?
Microwave Equipment, Data Communication Equipment, Transmission Equipment, Storage Device, Server

4. Why should you buy from us not from other suppliers?
Microwave equipment:RTN910A/RTN905F/RTN950/RTN950A/RTN980/RTN980L/RTN320F/RTN380AX; Wavelength division equipment:OSN9800/OSN9600/ONS8800; OLT:MA5800X2/X7; Switch:S9310X/CE6881-48S6CQ-B/CE8851-32CQ8DQ-P/CE6863E-48S6CQ. OceanStor Dorado 6000 V6/2288H V6/5288V6

5. What services can we provide?
Accepted Delivery Terms: FOB,EXW;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T;
Language Spoken:English,Chinese
Ne40e-X3 Network Router with Huawei Netengine40e Integrated AC Chassis and Dual Power 21

Tags: